C2566 Repair Tips




Search: C2566
Results 1
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Hitachi C2566
Severe field cramp at bottom of the picture, but very stretched picture at the topC608 4.7uF, 63v. in field stage o/c